Remote-controlled battery master switch with deep discharge protection | 260A / 12V | THR 265-12

✅ 260A max. current | ✅ Battery protection against deep discharge & overvoltage | ✅ Control LED


Varianten-ID 100980

inkl. ${ $store.getters.currentItemVariation.prices.default.vat.value }% MwSt. excl. Shipping

Weight , Versand als Paket

Transportzeit 1-2 Werktage**

Add suitable accessories

Remote-controlled battery main switch with deep discharge protection | 260A / 12V

Protection against battery deep discharge or overvoltage | manual emergency operation | control LED


The remote-controlled battery main switch THR 265-12 enables the connected loads to be switched on and off conveniently by remote control from any point in the vehicle or boat. It also has integrated undervoltage and overvoltage protection, which automatically controls the main switch and thus protects the battery or the connected loads from damage.

Special features:

  • Remote-controlled switching on and off
  • 260A max. current
  • Battery protection against deep discharge
  • Battery protection against overvoltage
  • Control LED
  • Visual display of the switch-off delay time
  • Manual emergency operation

Remote operation using an optional switch:

Using an optional switch, such as the WS22RG pressure switch shown here as an example or the FAR remote control panel, the battery main switch can be operated reliably and clearly from a distance (optional, does not have to be used).


Automatic disconnection in the event of undervoltage with automatic reconnection:

If the battery voltage drops below 11.2V, the main switch - with a delay time of 300 seconds - automatically disconnects. The delay phase prevents a brief voltage dip - e.g. by switching on a large consumer - from triggering the disconnection. During the delay period, the LED integrated in the main switch and the optional external LED flash. The connection is automatically re-established as soon as the battery voltage has risen above 12.5 V again (delay time 10 seconds).

Automatic disconnection in the event of overvoltage with automatic reconnection:

If the battery voltage rises above 15.6V, the main switch - with a delay time of 60 seconds - automatically disconnects the connection. The delay phase prevents brief voltage peaks - e.g. when connecting chargers - from triggering the disconnection. During the delay time, the LED integrated in the main switch and the optional external LED flash. The connection is automatically re-established as soon as the battery voltage drops below 14.5V again (delay time 10 seconds).


Manual emergency operation

In the event of failure of the control electronics, the relay can be switched directly by means of an external cable bridge between the minus and the upper screw heads of the centre relay terminal by means of a short switching pulse (1 second).


Operation

The internal LED flashes briefly to indicate that the relay is ready for operation. When the relay is switched on, the internal LED and the LED light on the remote control panel light up continuously.

While the delay time for switching off is running, both the internal LED and the LED light of the remote control panel flash on the THR models. If the main switch has switched off due to undervoltage or overvoltage, the main switch can be switched on again by switching it on again at the control panel. If the voltage is still outside the valid range, the system switches off again after the delay time.


Scope of delivery

  • Remote-controlled battery main switch with deep discharge protection | 260A / 12V | THR 265-12
  • Of course, you can also obtain operating instructions in German from us in the download area

Manufacturer's warranty

  • two years from date of purchase

Further helpful tips can be found in our FAQ questions/answers page under the following FAQ link .

THR 265 12V

Operating voltage:
8 - 16V
Switch-off at undervoltage (T = 300s):
11,2V
Switching back on after undervoltage (T = 10s):
12,5V
Switch-off in the event of overvoltage (T = 60s):
15,6V
Reconnection after overvoltage (T = 10s):
14,5V
(T = delay time)
Rated current:
260 A with cable cross-section 95 mm² @ 20°C
Overload current 5s:
400 A (5s), 1500 A (0.2s)
ParameterCurrent consumption:
Stand by: 1.5mA @ 13V, relay ON: 2.5mA @ 13V,
Connection terminals:
M8, max. 12.6 Nm
Protection class:
IP 20
Dimensions (LxWxH):
124 x 95 x 60 mm
CE conformity:
This device fulfils the requirements of the
EU Directive: 2004/108/EC
"Electromagnetic compatibility"

Varianten ID

100980

Sie haben noch Fragen zum Ablauf der Bestellung oder zum Artikel?

Kontaktieren Sie doch einfach einen Mitarbeiter aus unserem Kundenserviceteam.

Wir sind für Sie telefonisch von Mo. bis Do. von 8:00 bis 12:30 Uhr und 13:30 bis 18:00 Uhr sowie
Freitags von 8:00 bis 12:30 Uhr und 13:30 bis 17:00 Uhr erreichbar.
Tel.: 06024 6341 560 oder per Fax unter 06024 6341 569
Natürlich stehen wir Ihnen auch per e-mail zur Verfügung: kontakt@fraron.de


Sie würden die Ware gerne vorher ansehen oder sich persönlich vor Ort beraten lassen?

Kein Problem, gerne können Sie sich alle Produkte in unserer Ausstellungsfläche ansehen.
Wir stehen Ihnen natürlich persönlich für ein Beratungsgespräch zur Verfügung.
Mo. bis Do. von 8:00 bis 12:30 Uhr und 13:30 bis 18:00 Uhr
Freitags von 8:00 bis 12:30 Uhr und 13:30 bis 17:00 Uhr


Welche Zahlungsarten stehen Ihnen zur Verfügung?

Barzahlung / EC Kartenzahlung bei Abholung in der Ladenfiliale in Schöllkrippen
Überweisung / Vorkasse
Nachnahme (Sie zahlen bei Erhalt direkt beim Paketzusteller)
PayPal inklusive Käuferschutz (für Länder der EU sowie Liechtenstein, Norwegen, Island)
Kreditkarte (Visa / Master)

Wie lange dauert der Versand der Ware?

Der Lagerstatus ist online auf der jeweiligen Produktseite angegeben. Lagernde Produkte, werden in Abhängigkeit von der Zahlart sofort oder nach Zahlungseingang versendet. Der Versand paketversandfähiger Waren erfolgt in alle Lieferländer per DHL. Die Paketlaufzeiten in Deutschland liegen bei 1-2 Werktagen. DHL stellt auch Samstag in Deutschland zu. Speditionsgut versenden wir über die Spedition Emons, die Laufzeiten liegen bei 2-3 Werktagen innerhalb Deutschlands, im Ausland kann dies nicht pauschal angegeben werden, bitte sprechen Sie uns an.

<div class="pdf"> <a href="https://www.dropbox.com/scl/fi/8n4wd2zpmcgmqgrmr4n1i/FHR-THR265_1D.pdf?rlkey=3418emlp99paxf4ou5cp2sqvc&dl=0"target="_blank">Manual Battery master switch THR 265 12V</a> </div>

 high quality goods
 huge warehouse
 best service

Similar articles

Currently often bought

NACHNAME RECHNUNG